Search results for "Heart-Assist Devices"
showing 10 items of 16 documents
Relationship between device acceptance and patient-reported outcomes in Left Ventricular Assist Device (LVAD) recipients
2019
AbstractThe number of Left Ventricular Assist Devices (LVADs) implanted each year is rising. Nevertheless, there are minimal data on device acceptance after LVAD implant, and on its relationship with patient-reported outcomes. We designed a cross-sectional study to address this knowledge gap and test the hypothesis that low device acceptance is associated with poorer quality of life, depression and anxiety. Self-report questionnaires were administered to assess quality of life (12-item Kansas City Cardiomyopathy Questionnaire quality of life subscale), level of anxiety (7-item Generalized Anxiety Disorder; GAD-7), level of depression (9-item Patient Health Questionnaire; PHQ-9) and device a…
Myocardial G Protein Receptor–Coupled Kinase Expression Correlates With Functional Parameters and Clinical Severity in Advanced Heart Failure
2010
In heart failure (HF), sympathetic hyperactivation induces deleterious effects in myocardial β-adrenergic signaling, with receptor down-regulation and desensitization mediated by G protein receptor-coupled kinases (GRKs). We hypothesised that changes in GRK isoforms may be associated with clinical status in advanced HF, using the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) scale.We included 31 patients with advanced HF undergoing transplantation. According to INTERMACS profiles, mRNA and protein levels of GRK isoforms in left ventricular (LV) myocardium were analyzed and compared with nonfailing LV samples.In failing LV myocardium, GRK2 and GRK5 (but not G…
Early cardiac unloading with ImpellaCP™ in acute myocardial infarction with ventricular septal defect
2020
Abstract Despite a relative contraindication, mechanical support with Impella™ left ventricular assist device has already been described for ischaemic ventricular septal defect treatment, either as a bridge to surgery, as intraoperative mechanical haemodynamic support, or to ensure intraprocedural haemodynamic stability during device closure. We describe two cases of ventricular septal defect complicating acute myocardial infarction, where the percutaneous ImpellaCP was implanted early (differently than previously described) with the aim of preventing haemodynamic instability, while deferring surgical repair. We present a report of haemodynamic, echocardiographic, biochemical, and clinical …
Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis
2017
The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …
Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device
2017
Abstract Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdomi…
Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…
2017
Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …
Medical and psychosocial predictors of mechanical circulatory support device implantation and competing outcomes in the Waiting for a New Heart Study
2011
Background Medical and psychosocial factors are related to 1-year outcomes in the Waiting for a New Heart Study. With increased use of mechanical circulatory support devices (MCSD) over the course of the study, we can now evaluate these variables as predictors of MCSD in an extended follow-up. Methods Analyses focused on 313 MCSD-free patients (82% men; aged 53 ± 11 years) newly listed for heart transplantation (HTx). Variables assessed at time of listing included psychosocial risk (depression, social isolation), quality of life, waiting list stress, and medical risk (Heart Failure Survival Score, pulmonary capillary wedge pressure). Cumulative incidence functions and cause-specific Cox mod…
Usefulness of regional right ventricular and right atrial strain for prediction of early and late right ventricular failure following a left ventricu…
2019
Background: Identifying candidates for left ventricular assist device surgery at risk of right ventricular failure remains difficult. The aim was to identify the most accurate predictors of right ventricular failure among clinical, biological, and imaging markers, assessed by agreement of different supervised machine learning algorithms. Methods: Seventy-four patients, referred to HeartWare left ventricular assist device since 2010 in two Italian centers, were recruited. Biomarkers, right ventricular standard, and strain echocardiography, as well as cath-lab measures, were compared among patients who did not develop right ventricular failure (N = 56), those with acute–right ventricular fail…
Should subcutaneous implantable cardioverter-defibrillators be implanted in patients who are candidates for continuous flow left ventricular assist d…
2017
Endocrine Challenges in Patients with Continuous-Flow Left Ventricular Assist Devices
2021
Heart failure (HF) remains a leading cause of morbidity, hospitalization, and mortality worldwide. Advancement of mechanical circulatory support technology has led to the use of continuous-flow left ventricular assist devices (LVADs), reducing hospitalizations, and improving quality of life and outcomes in advanced HF. Recent studies have highlighted how metabolic and endocrine dysfunction may be a consequence of, or associated with, HF, and may represent a novel (still neglected) therapeutic target in the treatment of HF. On the other hand, it is not clear whether LVAD support, may impact the outcome by also improving organ perfusion as well as improving the neuro-hormonal state of the pat…